CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C10592 Imaging flow compensation indicator ImgFlowCompnsatnInd Indicator of whether flow compensation was used in imaging acquisition Indicator of whether flow compensation was used in imaging acquisition Flow compensation Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C18719 Imaging slice orientation type other text ImgSliceOrientTypOTH The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition The free-text field related to 'Imaging slice orientation type', specifying other text. The slice orientation used in imaging acquisition Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 2.00 2022-07-01 15:08:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C02499 Imaging pulse sequence type ImgPulseSeqTyp Type of imaging pulse sequence used Type of imaging pulse sequence used DTI sequence parameters, Sequence: Spin echo;STEAM;Other, specify Spin echo;STEAM;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:47:35.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C10964 Imaging eddy current induced spectral distortion correction indicator ImgEddyCurIndSpDCoInd Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation) Indicator as to whether image post-processing has included co-registering to b=0 image and correction for subject motion and eddy current induced distortion (affine transformation DWI co-registered to b=0 image and corrected for subject motion and eddy current induced distortion (affine transformation) Yes;No Yes;No Alphanumeric

Affine transformation

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C10576 Imaging in plane resolution axis 1 measurement ImgInPlaneRsltnAxis1Measr Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition Measurement of axis 1 of in-plane spatial resolution used in imaging acquisition DTI sequence parameters, In-plane resolution Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter
C18656 Imaging diffusion fifth b value ImgDiffusionFifthBVal Value, in square millimeters per second, of the fifth b-value used in diffusion acquisition Value, in square millimeters per second, of the fifth b-value used in diffusion acquisitio Numeric Values Adult;Pediatric Supplemental 1.00 2014-01-08 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10593 Imaging fat signal suppressed indicator ImgFatSignalSuppressedInd Indicator as to whether or not fat signal was suppressed in imaging acquisition Indicator as to whether or not fat signal was suppressed in imaging acquisition Fat signal suppressed Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected