CDE Detailed Report

Disease: General (For all diseases)
Subdomain Name: Imaging Diagnostics
CRF: Diffusion Tensor Imaging (DTI)

Displaying 51 - 57 of 57
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C08236 Imaging scanner software name ImgScannerSftwrName Name of the scanner software that runs the imaging camera Name of the scanner software that runs the imaging camera Name of the scanner software Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C15572 Imaging diffusion direction count ImgDiffusionDirCt Count of diffusion directions in the associated diffusion imaging study Count of diffusion directions in the associated diffusion imaging study DTI sequence parameters, Number of diffusion-weighting gradient directions Numeric Values

Record the number of diffusion-weighting gradient directions

No references available Adult;Pediatric Supplemental 3.00 2013-07-16 14:01:43.01 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C18657 Imaging diffusion sixth b value ImgDiffusionSixthBVal Value, in square millimeters per second, of the sixth b-value used in diffusion acquisition Value, in square millimeters per second, of the sixth b-value used in diffusion acquisitio Numeric Values Adult;Pediatric Supplemental 1.00 2014-01-08 00:00:00.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10577 Imaging signal averages number ImgSignalAvgNum Number of signal acquisitions averaged in imaging acquisition Number of signal acquisitions averaged in imaging acquisition DTI sequence parameters, Number of signal averages Numeric Values

Record the number of signal averages

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C10594 Imaging parallel acquisition used indicator ImgParallelAcquistionUsedInd Indicator of whether a parallel acquisition method is used in imaging acquisition Indicator of whether a parallel acquisition method is used in imaging acquisition Parallel acquisition used Yes;No Yes;No Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08238 Imaging repetition gap duration ImgRepetitionGapDur Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition DTI sequence parameters, Repetition time Numeric Values

TR

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:45.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond
C17793 Imaging diffusion fourth b value ImgDiffusionFourthBVal Value, in square millimeters per second, of the fourth b-value used in diffusion acquisition Value, in square millimeters per second, of the fourth b-value used in diffusion acquisitio DTI sequence parameters, fourth b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
CSV