CDE Catalog

***Please contact the NINDS CDE Team (NINDSCDE@emmes.com) if you encounter any search difficulties.***

The CDE Catalog is a directory of the available NINDS CDEs. Users can search the Catalog to isolate a subset of the CDEs (e.g., all stroke-specific CDEs, etc.), and to view and download details about the CDEs.

Select any filter below to search the CDE Catalog.

For best results, clear form between searches. In addition, when specifying NeuroRehab, Sport-Related Concussion (SRC) or Traumatic Brain Injury (TBI) as the Disease, please select a Subdisease as well.

NeuroRehab Comprehensive includes all NeuroRehab CDE recommendations. NeuroRehab General includes all NeuroRehab CDE recommendations that are not disease specific. All other NeuroRehab Subdiseases include recommendations specific to existing NINDS CDE project disorders.

Choose your Time Frame for your SRC study (Acute (time of injury until 72 hours), Subacute (after 72 hours to 3 months), and Persistent/Chronic (3 months and greater post-concussion) or Comprehensive if your study falls across the study time frames.

Choose your type of TBI study (Acute Hospitalized, Concussion/Mild TBI, Moderate/Severe TBI: Rehabilitation, or Epidemiology) or Comprehensive if your study falls outside of the study types or incorporates aspects of more than one type of study.

Search Form

Displaying 101 - 125 of 869
Operations
Selected 25 rows in this page.  
The search results below can be downloaded by clicking the checkboxes on the far left side of the table. Select the header checkbox to select all CDEs listed on the first page. Then choose CDE Detailed Report from the Choose an operation dropdown menu.
CDE ID CDE Name Definition Classification CRF Name Copyrighted or trademarked Disease Name Subdisease Name
C12744 Electrophysiology neuromuscular jitter mean consecutive difference abnormal count

Count of pairs/endplates with abnormal mean consecutive difference (MCD) recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12703 Electrophysiology sensory nerve segment length measurement

The sensory nerve segment length measured during the sensory nerve conduction study

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12755 Electrophysiology Valsalva ratio

The Valsalva ratio measured during autonomic function testing

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C08242 Imaging acquisition duration

Duration of the imaging scan in minutes

Supplemental Diffusion Tensor Imaging (DTI) General (For all diseases) General (For all diseases)
C12712 Electrophysiology blink reflex test R1 latency value

Duration of R1 latency in the blink reflex test

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C10583 Imaging base resolution value

Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI)

Supplemental Diffusion Tensor Imaging (DTI) General (For all diseases) General (For all diseases)
C12720 Electrophysiology repetitive nerve stimulation study preactivation area measurement

Measurement, in mVms, of the area of the preactivation being described for the repetitive nerve study being recorded

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12541 Imaging contrast agent injection time

Time contrast medium was administered

Supplemental Magnetic Resonance Imaging (MRI) General (For all diseases) General (For all diseases)
C20407 Adverse event reporting identifier name

A name of an authorized group or person reporting the adverse event

Supplemental Serious Adverse Events General (For all diseases) General (For all diseases)
C12729 Needle electromyography spontaneous activity type

The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C10777 Electrophysiology study type

Type of electrophysiology study conducted

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12696 Electrophysiology motor nerve segment name

The name of the segment used for the motor nerve conduction study

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12745 Electrophysiology neuromuscular jitter study blocking count

Count of pairs/endplates with blocking recorded for the neuromuscular jitter study being described

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12704 Electrophysiology sensory nerve onset or peak latency value

The onset or peak latency measured during the sensory nerve conduction study

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12713 Electrophysiology blink reflex test ipsilateral R2 latency value

Duration of ipsilateral R2 latency in the blink reflex test

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C10584 Imaging phase resolution percentage value

The value in percent of the phase resolution used in imaging acquisition

Supplemental Diffusion Tensor Imaging (DTI) General (For all diseases) General (For all diseases)
C12721 Electrophysiology repetitive nerve activation technique type

Indicator of the activation technique used in the repetitive nerve study being recorded

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C10583 Imaging base resolution value

Value in points of the base resolution used in imaging acquisition as part of Diffusion Tensor Imaging (DTI)

Supplemental Magnetic Resonance Imaging (MRI) General (For all diseases) General (For all diseases)
C12508 Imaging radio frequency coil function type

The function of the radio frequency (RF) coil used

Supplemental Magnetic Resonance Imaging (MRI) General (For all diseases) General (For all diseases)
C12730 Needle electromyography motor unit action potential amplitude measurement

The amplitude value of the motor unit action potential (MUAP) measure during needle electromyography

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12697 Electrophysiology motor nerve latency value

The length of time needed for the electrical impulse to travel between the stimulation and recording sites measured during the motor nerve conduction study

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12705 Electrophysiology sensory nerve velocity measurement

The signal transmission speed measured during the sensory nerve conduction study

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12714 Electrophysiology blink reflex test contralateral R2 latency value

Duration of contralateral R2 latency in the blink reflex test

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12765 Electrophysiology short pre-exercise compound muscle action potential time

The time intervals used to measure compound muscle action potential (CMAP) during pre-exercise

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
C12722 Electrophysiology repetitive nerve high frequency

Value, in Hz, of the specific frequency used for the high frequency stimulation activation technique, if applicable, in the repetitive nerve study being recorded

Supplemental Electrophysiology General (For all diseases) General (For all diseases)
Displaying 101 - 125 of 869

The NINDS CDE Team does not post proprietary instruments/scales recommended by the CDE Working Groups on this website. This includes, but is not limited to, copyrighted or trademarked instruments/scales. Information about recommended instruments can be found in the Notice of Copyright (NOC) documents under ‘CRF Module/Guideline’ on each disorder’s data standards page. For any questions regarding these instruments/scales please contact the corresponding owner/author. The NINDS CDE Team is not responsible for the availability or content of these external sites, nor does the NINDS CDE Team endorse, warrant or guarantee the products, services or information described or offered at these other internet sites.