of0
Export
 
CDE Detailed Report
This report contains detailed information about the selected CDEs.
Note: If at least one CDE was selected from a copyright- or trademark-protected instrument/scale then all of the CDEs from that instrument/scale are included in this report.
Disease: Spinal Cord Injury
SubDisease: Spinal Cord Injury
Sub-Domain: Spinal Imaging/Spinal Cord Imaging
CRF: Diffusion Tensor Imaging
Item count: 33 (33 distinct CDEs)
CDE ID
CDE Name
Variable Name
Definition / Description
Question Text
Permissible Value
Description
Data Type
Instructions
References
Population
Classification (e.g., Core)
Version #
Version Date
Aliases for Variable Name
CRF Module / Guideline
© or TM
Sub-Domain
Domain
Previous Title
Size
Input Restrictions
Min Value
Max Value
Measurement Type
LOINC ID
SNOMED
caDSR ID
CDISC ID
C02494
Imaging study date and time
ImgStdyDateTime
Date (and time, if applicable and known) the radiologic study was obtained.
Imaging study date and time
  
Date or Date & Time
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
8/28/2013
Refer to SCI CDE Annotated Form
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging study date and time
 
Free-Form Entry
       
C02496
Imaging scanner manufacturer name
ImgScannerManufName
Name of manufacturer of imaging scanner
Name of scanner manufacturer
Agfa;Hitachi;Philips;Other, specify;Carestream;Toshiba;Hologic;Siemens;GE;Konica Minolta;
Agfa;Hitachi;Philips;Other, specify;Carestream;Toshiba;Hologic;Siemens;GE;Konica Minolta;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging scanner manufacturer name
 
Single Pre-Defined Value Selected
       
C18716
Imaging scanner manufacturer other text
ImgScannerManufOTH
The free-text field related to 'Imaging scanner manufacturer name' specifying other text. Name of manufacturer of imaging scanner
Other
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
5/27/2014
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
 
4000
Free-Form Entry
       
C08236
Imaging scanner software name
ImgScannerSftwrName
Name of the scanner software that runs the imaging camera
Name
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging camera software name
4000
Free-Form Entry
       
C02498
Imaging scanner software version number
ImgScannerSftwrVrsnNum
Version number of the imaging scanner software
Version number
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging scanner software version number
4000
Free-Form Entry
       
C02495
Imaging scanner strength value
ImgScannerStrgthVal
Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported
Magnetic field strength of scanner used
1.5T;3.0T;4.0T;7.0T;Other, specify;
1.5T;3.0T;4.0T;7.0T;Other, specify;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
8/28/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging scanner strength value
 
Single Pre-Defined Value Selected
  
Tesla
    
C18718
Imaging scanner strength other text
ImgScannerStrgthOTH
The free-text field related to 'Imaging scanner strength value' specifying other text. Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported
Other
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
5/27/2014
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
 
4000
Free-Form Entry
  
Tesla
    
C02499
Imaging pulse sequence type
ImgPulseSeqTyp
Type of imaging pulse sequence used
Sequence
rFOV;EPI;Spin echo;
Reduced field of view (rFOV);Echo Planar Imaging (EPI);Spin echo;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
8/28/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging sequence type
 
Multiple Pre-Defined Values Selected
       
C10685
Imaging slice orientation type
ImgSliceOrientTyp
The slice orientation used in imaging acquisition
Slide orientation
Axial;Coronal;Sagittal;Oblique;
Axial;Coronal;Sagittal;Oblique;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging slice orientation type
 
Single Pre-Defined Value Selected
       
C19326
Imaging frame of reference type
ImgFrameReferenceTyp
The type related to imaging of frame of reference.
Frame of reference
Orthogonal;Rotated;
Orthogonal;Rotated;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
6/9/2014
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C08238
Imaging repetition gap value
ImgRepetitionGapVal
Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition
Repetition time (TR)
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging repetition time
 
Free-Form Entry
  
millisecond
    
C08239
Imaging echo duration
ImgEchoDur
Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition
Echo time (TE)
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging echo time
 
Free-Form Entry
  
millisecond
    
C08240
Imaging flip angle measurement
ImgFlipAngleMeasr
Measurement of the angle, in degrees, over which the radio frequency changes proton spin angle
FA
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging flip angle measurement
 
Free-Form Entry
  
degree
    
C19370
Frequency field of view phase measurement
FrequencyFOVPhaseMeasr
Phase measurement of spatial encoding area of frequency image
Freq FOV mm
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
6/13/2014
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
  
Free-Form Entry
  
mm
    
C08241
Imaging field of view axis 1 measurement
ImgFieldViewAxis1Measr
Axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters
Matrix size
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
FOV
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging field of view measurement
 
Free-Form Entry
  
millimeter
    
C18611
Imaging field of view axis 2 measurement
ImgFieldViewAxis2Measr
Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters
Matrix size
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
9/12/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
  
Free-Form Entry
  
millimeter
    
C08245
Imaging slice count
ImgSliceCt
Count representing the total number of single image planes captured during imaging acquisition
Number of slices
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging slice number
 
Free-Form Entry
       
C08244
Imaging slice thickness value
ImgSliceThicknessVal
Value of the thickness of the slice measured in millimeters (mm)
Slice thickness
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging slice thickness value
 
Free-Form Entry
0
99
millimeter
    
C10837
Imaging gap between slices measurement
ImgGapBetwnSlicesMeasr
Measurement of the gap between slices used in imaging acquisition
Slice gap
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging gap between slices measurement
 
Free-Form Entry
  
millimeter
    
C10838
Imaging voxel size axis 1 measurement
ImgVoxelSizeAxis1Measr
Measurement, in millimeters, of the axis 1 dimension of the voxel within the anatomy of interest
Voxel size
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging voxel size measurement
 
Free-Form Entry
  
millimeter
    
C17858
Imaging voxel size axis 2 measurement
ImgVoxelSizeAxis2Measr
Measurement, in millimeters, of the axis 2 dimension of the voxel within the anatomy of interest
Voxel size
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
  
Free-Form Entry
  
millimeter
    
C17859
Imaging voxel size axis 3 measurement
ImgVoxelSizeAxis3Measr
Measurement, in millimeters, of the axis 3 dimension of the voxel within the anatomy of interest
Voxel size
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
  
Free-Form Entry
  
millimeter
    
C19331
Imaging number of excitations count
ImgNEXCt
The count as related to number of diffusion tensor imaging acquisitions or number of excitations.
NEX
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
6/9/2014
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
  
Free-Form Entry
0
5
     
C10591
Imaging phase encode direction text
ImgPhasEncdeDirctTxt
Text description of the phase encode direction used in imaging technique acquisition
Phase-encode direction
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging phase encode direction text
4000
Free-Form Entry
       
C10593
Imaging fat signal suppressed indicator
ImgFatSignalSuppressedInd
Indicator as to whether or not fat signal was suppressed in imaging acquisition
Fat suppression
Yes;No;Unknown;Not applicable;
Yes;No;Unknown;Not applicable;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Diffusion Tensor Imaging
Spinal Imaging/Spinal Cord Imaging
Assessments and Examinations
Imaging fat signal suppressed indicator
 
Single Pre-Defined Value Selected
       
12-19-2018
Page 1 of 2