of0
Export
 
CDE Detailed Report
This report contains detailed information about the selected CDEs.
Note: If at least one CDE was selected from a copyright- or trademark-protected instrument/scale then all of the CDEs from that instrument/scale are included in this report.
Disease: Spinal Cord Injury
SubDisease: Spinal Cord Injury
Sub-Domain: Electrodiagnostics
CRF: Peripheral Nerve Studies
Item count: 34 (34 distinct CDEs)
CDE ID
CDE Name
Variable Name
Definition / Description
Question Text
Permissible Value
Description
Data Type
Instructions
References
Population
Classification (e.g., Core)
Version #
Version Date
Aliases for Variable Name
CRF Module / Guideline
© or TM
Sub-Domain
Domain
Previous Title
Size
Input Restrictions
Min Value
Max Value
Measurement Type
LOINC ID
SNOMED
caDSR ID
CDISC ID
C10777
Electrophysiology study type
ElctrophysStdyTyp
Type of electrophysiology study conducted
 
Motor nerve conduction study;Sensory nerve conduction study;H-reflex study;Needle electromyography;
Motor nerve conduction study;Sensory nerve conduction study;H-reflex study;Needle electromyography;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Electrophysiology study type
 
Single Pre-Defined Value Selected
       
C12710
Electrophysiology assessment date and time
ElctrophysAssmtDateTime
Date the particular electrophysiology study was performed
Date of Test
  
Date or Date & Time
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Electrophysiology assessment date and time
 
Free-Form Entry
       
C10780
Electrophysiology anatomic site
ElctrophysAntmicSite
Area of the body (e.g., nerve or muscle) where the type of electrophysiology study is performed
Nerve/Muscle
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Electrophysiology anatomic site
255
Free-Form Entry
       
C02411
Laterality type
LatTyp
Laterality type relative to the anatomic site of the body examined or affected
Side
Right;Midline;Left;
Right;Midline;Left;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
8/28/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Laterality type
 
Single Pre-Defined Value Selected
       
C01539
Temperature measurement
TempMeasr
Measurement of the participant's/subject's body temperature.
Temperature
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
8/28/2013
SCI CDEs: TEMPMEAS
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Temperature measurement
 
Free-Form Entry
0
50
degree Celsius
  
2644401
 
C01580
Temperature unit of measure
TempUOM
Unit of measure for the temperature numerical value
Temperature units
F;C;
degrees Fahrenheit;degrees Celsius;
Alphanumeric
No instructions available
Unified Code for Units of Measure - http://unitsofmeasure.org/
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Temperature unit of measure
 
Single Pre-Defined Value Selected
     
2956267
 
C12696
Electrophysiology motor nerve segment name
ElctphysMotrNervSegmntName
The name of the segment used for the motor nerve conduction study
Segment/Stimulation/Recording site
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Electrophysiology segment name
255
Free-Form Entry
       
C12697
Electrophysiology motor nerve latency value
ElctphysMotrNervLatncyVal
The length of time needed for the electrical impulse to travel between the stimulation and recording sites measured during the motor nerve conduction study
Latency (normal limit)
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Motor nerve conduction study latency value
 
Free-Form Entry
  
microsecond
    
C12698
Electrophysiology motor nerve segment length measurement
ElctphysMotrNervSegmtLngMeasr
The nerve segment length measured during the motor nerve conduction study
Segment Length
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Motor nerve conduction study segment length measurement
 
Free-Form Entry
  
centimeter
    
C12699
Electrophysiology motor nerve amplitude measurement
ElctphysMotrNervAmpMeasr
The measured amplitude of signal response to test stimulation during the motor nerve conduction study
Amplitude (normal limit)
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Motor nerve conduction study amplitude measurement
 
Free-Form Entry
  
microVolt
    
C12700
Electrophysiology motor nerve dispersion result
ElctphysMotrNervDisprsnReslt
Amount of test signal dispersion measured during the motor nerve conduction study
Dispersed?
  
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Motor nerve conduction study dispersion result
255
Free-Form Entry
       
C12701
Electrophysiology motor nerve F-wave minimum latency value
ElctphyMotrNervFwavMinLatncVal
The length of time needed for the impulse to travel from the site, to the spine, and back to the site measured during the motor nerve conduction study
F wave minimum latency
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Motor nerve conduction study F-wave minimum latency value
 
Free-Form Entry
  
millisecond
    
C19368
Electrophysiology repetitive stimulation count
ElctrophysRepetitivStimulCt
The number of repetitions of a specific stimulus applied in a single series.
N stimulations
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
6/13/2014
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
  
Free-Form Entry
       
C19369
Electrophysiology motor nerve F-wave persistence percentage value
ElctrophysMtrNvFWvPrsistPctVal
The percentage of measurable F responses following a series of stimuli that is related to the antidromic excitability of a particular motor neuron pool.
Persistency (%)
  
Numeric Values
No instructions available
No references available
Adult;Pediatric
Supplemental
1.0
6/13/2014
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
  
Free-Form Entry
0
100
percent
    
C12702
Electrophysiology sensory nerve impulse direction type
ElctphysSensryNervImpulsDirTyp
The impulse direction put on the nerve during the sensory nerve conduction study
Impulse Direction
Orthodromic;Antidromic;
Orthodromic;Antidromic;
Alphanumeric
No instructions available
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Sensory nerve conduction study impulse direction type
 
Single Pre-Defined Value Selected
       
C12703
Electrophysiology sensory nerve segment length measurement
ElctphysSensNervSegmtLgthMeasr
The sensory nerve segment length measured during the sensory nerve conduction study
Segment Length
  
Numeric Values
Record the length in centimeters (cm). Record for each segment tested
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Sensory nerve conduction study segment length measurement
 
Free-Form Entry
  
centimeter
    
C12704
Electrophysiology sensory nerve onset or peak latency value
ElctphysSensNervOnsPkLatncVal
The onset or peak latency measured during the sensory nerve conduction study
Onset or Peak Latency
  
Numeric Values
Record the onset or peak latency in milliseconds (ms). Record for each segment tested
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Sensory nerve conduction study onset or peak latency value
 
Free-Form Entry
  
microsecond
    
C12705
Electrophysiology sensory nerve velocity measurement
EltrphysSensryNervVeloctyMeasr
The signal transmission speed measured during the sensory nerve conduction study
Velocity (normal limit)
  
Numeric Values
Record the velocity in meters per second (m/s). Record for each segment tested
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Sensory nerve conduction study velocity measurement
 
Free-Form Entry
  
meter per second
    
C12706
Electrophysiology sensory nerve amplitude measurement
ElctphysSensryNervAmpMeasr
The amplitude measured during the sensory nerve conduction study
Amplitude (normal limit)
  
Numeric Values
Record the measured amplitude in millivolts (mV). Record for each segment tested
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Sensory nerve conduction study amplitude measurement
 
Free-Form Entry
       
C12693
Electrophysiology H-reflex nerve segment name
ElctphysHReflxNervSegmtNam
The nerve segment used for the H-reflex test
Nerve Segment
  
Alphanumeric
Record the name of the nerve segment used for H-reflex testing
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
H-reflex nerve segment name
255
Free-Form Entry
       
C12707
Electrophysiology H-reflex latency left value
ElctphysHReflxLatncyLftVal
The H-reflex duration of latency for the left side of the body
Latency left
  
Numeric Values
Record the latency for the left side of the body in milliseconds (ms)
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
H-reflex latency left value
 
Free-Form Entry
  
millisecond
    
C12708
Electrophysiology H-reflex latency right value
ElctphysHReflxLatncyRtVal
The H-reflex duration of latency for the right side of the body
Latency right
  
Numeric Values
Record the latency for the right side of the body in milliseconds (ms)
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
H-reflex latency right value
 
Free-Form Entry
  
millisecond
    
C12728
Needle electromyography electrode type
NdlElctrmygrphyElectrdTyp
Type of electrode used for the needle electromyography
Electrode Type
Concentric;Monopolar;
Concentric;Monopolar;
Alphanumeric
Choose one
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Needle electromyography electrode type
 
Single Pre-Defined Value Selected
       
C12729
Needle electromyography spontaneous activity type
NdlElctrmygrphySATyp
The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography
Spontaneous Activity (SA)
Fibrillation potentials;Positive sharp waves;Fasciculation potentials;Other, specify;
Fibrillation potentials;Positive sharp waves;Fasciculation potentials;Other, specify;
Alphanumeric
Answer for both left and right sides of the body
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
Needle electromyography spontaneous activity (SA) type
 
Multiple Pre-Defined Values Selected
       
C18871
Needle electromyography spontaneous activity other text
NdlElctrmygrphySAOTH
The free-text field related to 'Needle electromyography spontaneous activity type' specifying other text. The type of spontaneous activity (SA) experienced by the participant/subject when undergoing needle electromyography
Spontaneous Activity (SA), Other
  
Alphanumeric
Answer for both left and right sides of the body
No references available
Adult;Pediatric
Supplemental
3.0
7/24/2013
Aliases for variable name not defined
Peripheral Nerve Studies
Electrodiagnostics
Outcomes and End Points
 
4000
Free-Form Entry
       
12-19-2018
Page 1 of 2