Disease: Myotonic Muscular Dystrophy
Sub-Domain: Muscle Strength Testing
CRF: Hand Held Dynamometry
Item count: 9 (9 distinct CDEs)
CDE ID
CDE Name
Variable Name
Definition / Description
Question Text
Permissible Value
Description
Data Type
Instructions
References
Population
Classification (e.g., Core)
Version #
Version Date
Aliases for Variable Name
CRF Module / Guideline
© or TM
Sub-Domain
Domain
Previous Title
Size
Input Restrictions
Min Value
Max Value
Measurement Type
LOINC ID
SNOMED
caDSR ID
CDISC ID
C10864
Dynamometry hand held muscle test performed indicator
DynmtryHandHldMuscTesPerfInd
Indicator of whether the hand held dynamometry testing was done.
Was the muscle testing done?
Yes;No;
Yes;No;
Alphanumeric
Choose one
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5.
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Hand held dynamometry performed indicator
 
Single Pre-Defined Value Selected
       
C10865
Dynamometry hand held muscle test performed date
DynmtryHandHldMuscTesPerfDate
Date (and time, if applicable and known) the hand held dynamometry was performed on the participant/subject
Date Performed
  
Date or Date & Time
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Hand held dynamometry date and time
 
Free-Form Entry
       
C17790
Dynamometry hand held time
DynmtryHandHldTime
Time the hand held dynamometry was performed.
Time Performed
  
Date or Date & Time
Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).
ISO 8601 - http://www.iso.org/iso/iso_catalogue.htm
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
  
Free-Form Entry
       
C02411
Laterality type
LatTyp
Laterality type relative to the anatomic site of the body examined or affected
Muscle
Right;Left;
Right;Left;
Alphanumeric
Record the hand held dynamometry result for each muscle and side
Shefner J, Cudkowicz ME, Maragakis N, Cedarbaum JM, Lee J, Jones D, Watson ML, Shaver K, Chen M, Saikali K, Mao J, Russell AK, Hansen L, Malik F, Wolff AA, for the NEALS/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in Amyotrophic Lateral Sclerosis. (submitted for publication)
Adult;Pediatric
Supplemental
3.0
8/28/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Laterality type
 
Single Pre-Defined Value Selected
       
C10867
Dynamometry hand held muscle test performed anatomic site
DynmtrHandHldMusTesPerfAntSite
The type of muscle tested using hand held dynamometry.
Muscle
Shoulder Flexion;Elbow Flexion;Elbow Extension;Wrist Extension;Hip Flexion;Knee Extension;Ankle Dorsiflexion;Knee Flexion;First Dorsal Interosseous;Other, specify;
Shoulder Flexion (SF);Elbow Flexion (EF);Elbow Extension (EE);Wrist Extension (WE);Hip Flexion (HF);Knee Extension (KE);Ankle Dorsiflexion (AD);Knee Flexion (KF);First Dorsal Interosseous (FDI);Other, specify;
Alphanumeric
Record the hand held dynamometry result for each muscle and side
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5.
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Hand held dynamometry anatomic site
 
Single Pre-Defined Value Selected
       
C10171
Trial number
TrialNum
The number representing the sequence for any repeated measure test or assessment when it is performed multiple times.
Trial
Trial 1;Trial 2;
Trial 1;Trial 2;
Alphanumeric
It is recommended that two hand held dynamometry trials be performed for each muscle
Supplemental-Highly Recommended
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5. Shefner J, Cudkowicz ME, Maragakis N, Cedarbaum JM, Lee J, Jones D, Watson ML, Shaver K, Chen M, Saikali K, Mao J, Russell AK, Hansen L, Malik F, Wolff AA, for the NEALS/Cytokinetics Study Team. Safety, tolerability and pharmacodynamics of a skeletal muscle activator in Amyotrophic Lateral Sclerosis. (submitted for publication) http://www.meddean.luc.edu/lumen/MedEd/medicine/pulmonar/fellow/pftm_f.htm
Adult;Pediatric
Supplemental
3.0
7/25/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Trial number
 
Single Pre-Defined Value Selected
       
C10869
Dynamometry hand held muscle test result
DynmtryHandHldMuscTesReslt
The results of the trial performed by the participant/subject on the hand held dynamometer.
Result
  
Numeric Values
Answer should be recorded for each muscle type in pounds.
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5.
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Hand held dynamometry trial result
 
Free-Form Entry
  
pounds
    
C10871
Dynamometry hand held muscle test able to break technique indicator
DynmtryHandHldMuscTBrkTechInd
Indicator of whether the examiner overpowered the maximal effort by the participant/subject, thereby producing a measurement of eccentric muscle strength.
Break technique-Able to Break?
Yes;No;
Yes;No;
Alphanumeric
Choose one. Answer for each muscle type and each trial.
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5.
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Hand held dynamometry able to break technique indicator
 
Single Pre-Defined Value Selected
       
C10872
Dynamometry hand held no result reason
DynmtryHandHldNoResltRsn
Reason why there was no hand held dynamometry result for the muscle.
Reason No Result
Unable to test;Not done;
Unable to test;Not done;
Alphanumeric
Choose one. Answer for each muscle type and each trial
Beck M, Giess R, Wuerffel W, Magnus T, Ochs, G, Toyka KV. Comparison of Maximal Voluntary Isometric Contraction and Drachman's Hand-Held Dynamometry in Evaluating Patients with Amyotrophic Lateral Sclosis. Muscle Nerve. 1999; 22: 1265-1270. Bohannon RW. Hand-Held Dynamometry; Stability of Muscle Strength Over Multiple Measurements. Clinical Biomechanics. 1986: 2:74-77. Wang CY, Olson SL, Protas EJ. Test-Retest Strength Reliability: Hand-Held Dynamometry in Community-Dwelling Elderly Faller. Arch Phys Med Rehabil. 2002; 83: 811-5.
Adult
Supplemental
3.0
7/22/2013
Aliases for variable name not defined
Hand Held Dynamometry
Muscle Strength Testing
Outcomes and End Points
Hand held dynamometry no result reason
 
Single Pre-Defined Value Selected
       
12-10-2018