of0
Export
 
CDE Detailed Report
This report contains detailed information about the selected CDEs.
Note: If at least one CDE was selected from a copyright- or trademark-protected instrument/scale then all of the CDEs from that instrument/scale are included in this report.
Disease: Myalgic Encephalomyelitis/Chronic Fatigue Syndrome
Sub-Domain: Imaging Diagnostics
CRF: Low Resolution Electromagnetic Tomography (LORETA)
Item count: 25 (25 distinct CDEs)
CDE ID
CDE Name
Variable Name
Definition / Description
Question Text
Permissible Value
Description
Data Type
Instructions
References
Population
Classification (e.g., Core)
Version #
Version Date
Aliases for Variable Name
CRF Module / Guideline
© or TM
Sub-Domain
Domain
Previous Title
Size
Input Restrictions
Min Value
Max Value
Measurement Type
LOINC ID
SNOMED
caDSR ID
CDISC ID
C58153
Software low resolution electromagnetic tomography analysis name
SftwrLORETAAnlysName
Name of the software used for low resolution electromagnetic tomography (LORETA) analysis
Software for analysis:
LORETA-KEY software;swLORETA;Other;
LORETA-KEY software (LORETA, sLORETA, eLORETA);swLORETA;Other;
Alphanumeric
LORETA-KEY software available at www.uzh.ch/keyinst/loreta.htm. swLORETA now available at www.appliedneuroscience.com
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C58155
Software low resolution electromagnetic tomography analysis name other text
SftwrLORETAAnlysNameOthTxt
The free-text field related to 'Software low resolution electromagnetic tomography analysis name' specifying the name of other software used for low resolution electromagnetic tomography (LORETA) analysis
Other:
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
C58154
Brain volume qualitative analysis category
BrnVolQualAnalysCat
Category of the brain volume analysed, in qualitative terms
Full brain volume / Partial brain volume
Full brain volume;Partial brain volume;
Full brain volume;Partial brain volume;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C58156
Brain part text
BrainPartTxt
Text describing the part of the brain examined if less than the full brain volume
Partial brain volume (portion to be examined if using other source analysis software)
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
C58157
Qualitative EEG time series data type
qEEGTimeSeriesDataTyp
Type of time series data exported from qualitative EEG (qEEG)
Exported time series from qEEG data
EEG artifact-free data with > .90 reliability estimates;2-second EEG segments windowing function;
EEG artifact-free data with > .90 reliability estimates;2-second EEG segments windowing function (to control for spectral leakage);
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Multiple Pre-Defined Values Selected
       
C58158
Data time series 2 second EEG windowing function type
DatTimSer2SecEEGWndwFunTyp
Type of 2-second EEG segment windowing function time-series data exported
2-second EEG segments windowing function
Cosine taper window function;Other taper window function;Hanning (Hamming) window function;Non-overlapping (successive) window function;
Cosine taper window function;Other taper window function;Hanning (Hamming) window function;Non-overlapping (successive) window function;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Multiple Pre-Defined Values Selected
       
C58159
Windowing function cosine taper percent value
WindowFuncCosTaprPctVal
Value, as a percentage, of 2-second EEG segments produced for time-series analysis using cosine taper windowing function
% cosine taper window
  
Numeric Values
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Free-Form Entry
0
100
Percent
    
C58160
Windowing function other taper percent overlap value
WndwFuncOthTaprPctOvrlpVal
Value, as a percentage, of overlap between 2-second EEG segments produced for time-series analysis using other taper windowing function
Other taper window function (% overlap)
  
Numeric Values
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Free-Form Entry
0
100
Percent
    
C58161
Windowing function Hanning Hamming percent overlap value
WndwFuncHanHamPctOvrlpVal
Value, as a percentage, of overlap between 2-second EEG segments produced for time-series analysis using Hanning (Hamming) windowing function
Hanning (Hamming) window function (% overlap)
  
Numeric Values
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Free-Form Entry
0
100
Percent
    
C58162
Low resolution electromagnetic tomography frequency band category
LORETAFreqBandCat
Category of frequency bands used for low resolution electromagnetic tomography (LORETA)
Define frequency bands as follows within LORETA
Conventional band settings;Researcher-defined bands;
Conventional band settings: delta = 1-3 Hertz, theta = 4-7 Hertz, alpha = 8-12 Hertz, beta-1 = 13-18 Hertz, beta-2 = 19-21 Hertz, beta-3 = 22-30 Hertz, omega = 1-30 Hertz;Researcher-defined bands, e.g., 1 Hertz, 2 Hertz, 3 Hertz, etcetera;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Multiple Pre-Defined Values Selected
       
C58164
Low resolution electromagnetic tomography researcher defined frequency band type
LORETARsrchrDefFrqBndTyp
Type, meaning frequencies in Hertz, of researcher-defined bands used for low resolution electromagnetic tomography (LORETA)
Researcher-defined bands, such as 1 Hz bands--1 Hz, 2 Hz, 3 Hz, etc. (name bands)
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
C58165
Montreal Neurological Institute average brain map use electrode placement indicator
MNIAvgBrnMapUsElctrdPlcmtInd
Indicator of whether the Montreal Neurological Institute (MNI) average brain map was used for electrode placement
Electrode coordinates: head model of eLORETA & electrode coordinates are based on the Montreal Institute average MNI brain map (MNI 152)
Yes;No;
Yes;No;
Alphanumeric
No instructions available
Mazziotta J, Toga A, Evans A, Fox P, Lancaster J, Zilles K, Woods R, Paus T, Simpson G, Pike B, Holmes C, Collins L, Thompson P, MacDonald D, Iacoboni M, Schormann T, Amunts K, Palomero-Gallagher N, Geyer S, Parsons L, Narr K, Kabani N, Le Goualher G, Feidler J, Smith K, Boomsma D, Hulshoff Pol H, Cannon T, Kawashima R, Mazoyer B. A four-dimensional probabilistic atlas of the human brain. J Am Med Inform Assoc. 2001;8(5):401-430. PMID: 11522763
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C58139
Quantitative EEG electrode other count
qEEGElectrodeOtherCt
The free-value field related to "Quantitative EEG electrode count category" specifying other count
Number of electrodes (from qEEG data, min 19 electrodes):
  
Numeric Values
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Free-Form Entry
       
C58166
Electrode placement head system type
ElctrodPlacmntSystmHeadTyp
Type of system used for electrode placement on the head
Use of:
10/20 system;Other system;
10/20 system;Other system (define);
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C58167
Electrode placement head system other text
ElctrodPlacmntSystmHeadOthTxt
The free-text field related to 'Electrode placement head system type' for specifying the type of system used for electrode placement on the head
Other system (define)
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
C58168
State analysis method type
StateAnalysisMethodTyp
Type of method used for state analysis
State analysis type:
Current density power time series;Current density power XYZ time series;Total linear connectivity;Instantaneous linear connectivity;Lagged linear connectivity;Total nonlinear connectivity;Instantaneous nonlinear connectivity;Lagged nonlinear connectivity;Total coherence;Instantaneous coherence;Lagged coherence;Total phase synchronization;Lagged phase synchronization;Instantaneous phase synchronization;Cross frequency analysis;Microstate segmentation;Global connectivity;Independent component analysis;Isolated effective coherence;Other;
Current density power time series;Current density power XYZ time series;Total linear connectivity;Instantaneous linear connectivity;Lagged linear connectivity;Total nonlinear connectivity;Instantaneous nonlinear connectivity;Lagged nonlinear connectivity;Total coherence;Instantaneous coherence;Lagged coherence;Total phase synchronization;Lagged phase synchronization;Instantaneous phase synchronization;Cross frequency analysis;Microstate segmentation;Global connectivity;Independent component analysis;Isolated effective coherence;Other;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Multiple Pre-Defined Values Selected
       
C58169
State analysis method other text
StateAnalysisMethdOthTxt
The free-text field related to 'State analysis method type' specifying other text
Other:
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
C13970
Brain region of interest type
BrainROITyp
Region of interest in the brain
Specify ROIs (regions of interest) within solution space
Frontal;Parietal;Temporal;Occipital;White matter;Basal ganglia;Pons;Brain stem;Unknown;Other, specify;
Frontal;Parietal;Temporal;Occipital;White matter;Basal ganglia;Pons;Brain stem;Unknown;Other, specify;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
3.0
8/28/2013
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
Imaging ROI region indicator
 
Multiple Pre-Defined Values Selected
       
C18895
Brain region of interest other text
BrainROIOTH
The free-text field related to 'Brain region of interest type' specifying other text. Region of interest in the brain
Other, specify:
  
Alphanumeric
Specify ROIs (regions of interest) within solution space
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
3.0
8/28/2013
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
4000
Free-Form Entry
       
C58383
Imaging interest region voxel select method type
ImgIntrstRegnVoxlSlctMethdTyp
Type of method used to select the voxels related to the region of interest
Voxels:
MNI coordinates used to define significantly active regions;Single Nearest Voxel method;All-Voxels-Within-A-Radius;
MNI coordinates used to define significantly active regions;Single Nearest Voxel method (each region of interest has a single voxel);All-Voxels-Within-A-Radius;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/8/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C54780
EEG samping rate category
EEGSamplingRateCategory
Category of sampling rate for the EEG
Sampling rate:
128 Hertz;256 Hz;512 Hz;1024 Hertz;Other, specify;
128 Hertz;256 Hertz;512 Hertz;1024 Hertz;Other, specify;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
4/12/2017
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C17438
EEG sampling rate
EEGSamplingRate
Electroencephalography (EEG) sampling rate, commonly recorded in Hz (250-2000 Hz)
Other:
  
Numeric Values
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
3.0
8/28/2013
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
EEG sample rate
 
Free-Form Entry
       
C58170
MATLAB script name
MatlabScriptName
Name(s) of MATLAB script(s) used
MATLAB scripts used:
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
C58142
Imaging comparison data source type
ImgComparisonDataSourceTyp
Type of data source for comparison with study imagery
Comparison parameters
Normative database;Controls;
Normative database;Controls;
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
  
Single Pre-Defined Value Selected
       
C58143
Imaging comparison data source name
ImgComparisonDataSourceName
Name of data source used for comparison with study imagery
If database used, name database
  
Alphanumeric
No instructions available
Congedo, M., Lubar, J., & Joffe, D. (2004). Low resolution electromagnetic tomography
neurofeedback. IEEE Trans Neural Syst Rehabil, 12(4), 387-397.

Grech, R., Cassar, T., Muscat, J., Camilleri, K.P., Zervakis, M., Xanthopoulos, P. (2008). Review on solving the inverse problem in EEG source analysis. J Neuroeng Rehabil 7(5): 25. Doi: 10.1186/1743-0003-5-25.

Pascual-Marqui, R. D., Lehmann, D., Koukkou, M., Kochi, K, Anderer, P., Saletu, B. et al. (2011). Assessing interactions in the braini with exact low-resolution electromagnetic tomography. Phil., Trans. R. Soc, 306: 3768-3784. Doi:10.1098/rsta.2011.0081
Adult;Pediatric
Supplemental–Highly Recommended
1.0
2/5/2018
Aliases for variable name not defined
Low Resolution Electromagnetic Tomography (LORETA)
Imaging Diagnostics
Assessments and Examinations
 
255
Free-Form Entry
       
12-14-2018
Page 1 of 1