CDE ID | CDE Name | Variable Name | Definition / Description | Question Text | Permissible Value | Description | Data Type | Instructions | References | Population | Classification (e.g., Core) | Version # | Version Date | Aliases for Variable Name | CRF Module / Guideline | © or TM | Sub-Domain | Domain | Previous Title | Size | Input Restrictions | Min Value | Max Value | Measurement Type | LOINC ID | SNOMED | caDSR ID | CDISC ID |
C18656 | Imaging diffusion fifth b value | ImgDiffusionFifthBVal | Value, in square millimeters per second, of the fifth b-value used in diffusion acquisition. | | | | Numeric Values | No instructions available | No references available | Adult;Pediatric | Supplemental | 1.0 | 1/8/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | | Free-Form Entry | | | square millimeter per second | | | | |
C18657 | Imaging diffusion sixth b value | ImgDiffusionSixthBVal | Value, in square millimeters per second, of the sixth b-value used in diffusion acquisition. | | | | Numeric Values | No instructions available | No references available | Adult;Pediatric | Supplemental | 1.0 | 1/8/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | | Free-Form Entry | | | square millimeter per second | | | | |
C02495 | Imaging scanner strength value | ImgScannerStrgthVal | Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Magnetic Field Strength of Scanner Used | 1.5T;3.0T;4.0T;7.0T;Other, specify; | 1.5T;3.0T;4.0T;7.0T;Other, specify; | Alphanumeric | Choose one | No references available | Adult;Pediatric | Supplemental | 3.0 | 8/28/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging scanner strength value | | Single Pre-Defined Value Selected | | | Tesla | | | | |
C18718 | Imaging scanner strength other text | ImgScannerStrgthOTH | The free-text field related to 'Imaging scanner strength value' specifying other text. Value, in Tesla (T), of the scanner's magnetic field strength used for the scan being reported | Other, specify | | | Alphanumeric | Choose one | No references available | Adult;Pediatric | Supplemental | 1.0 | 5/27/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | Tesla | | | | |
C10682 | Imaging anatomic site | ImgAntmicSite | Type of body part or anatomy scanned in the imaging study | Body part scanned | Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify; | Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify; | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging anatomic site | | Multiple Pre-Defined Values Selected | | | | | | | |
C18689 | Imaging anatomic site other text | ImgAntmicSitOTH | The free-text field related to 'Imaging anatomic site' specifying other text. Type of body part or anatomy scanned in the imaging study | Other, specify | | | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 1.0 | 5/27/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C10567 | Imaging radio frequency coil type | ImgRFCoilTyp | Type of radio frequency (RF) coil(s) used for the body part scanned | RF Receiver coil(s) and number of channels | Head coil;Neck coil;Spine array;Body coil (transmit);Other, specify; | Head coil;Neck coil;Spine array;Body coil (transmit);Other, specify; | Alphanumeric | Check all that apply. | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging RF receiver coil type | 4000 | Multiple Pre-Defined Values Selected | | | | | | | |
C18715 | Imaging radio frequency coil other text | ImgRFCoilOTH | The free-text field related to 'Imaging radio frequency coil type' specifying other text. Type of radio frequency (RF) coil(s) used for the body part scanned | Other, specify | | | Alphanumeric | Check all that apply. | No references available | Adult;Pediatric | Supplemental | 1.0 | 5/27/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of channels | 1;8;12;16;24;32;Other, specify; | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify; | Alphanumeric | Answer for each RF coil named | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging coil channel number | | Single Pre-Defined Value Selected | | | | | | | |
C18714 | Imaging radio frequency coil channel other text | ImgRFCoilChannelOTH | The free-text field related to 'Imaging radio frequency coil channel count' specifying other text. Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Other, specify | | | Alphanumeric | Answer for each RF coil named | No references available | Adult;Pediatric | Supplemental | 1.0 | 5/27/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C10683 | Imaging T2 weighted spin-echo acquired indicator | ImgT2WSpinEchoAcquireInd | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correction. | T2-weighted spin-echo acquired | Yes;No; | Yes;No; | Alphanumeric | For B0-susceptibility distortion correction. | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | DTI T2 weighted spin-echo acquired indicator | | Single Pre-Defined Value Selected | | | | | | | |
C10570 | Imaging contrast agent used indicator | ImgContrastAgentUsedInd | Indicator as to whether or not an imaging contrast agent was used for the scan as part of Diffusion Tensor Imaging (DTI). | Contrast Used | Yes;No;Unknown;Not applicable; | Yes;No;Unknown;Not applicable; | Alphanumeric | Choose one. If yes, record the name of the contrast agent and its dosage. | No references available | Adult;Pediatric | Supplemental | 3.0 | 8/28/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging contrast agent used indicator | | Single Pre-Defined Value Selected | | | | | | | |
C17798 | Imaging contrast agent name | ImgContrastAgentName | Name of imaging contrast agent used | Contrast Used: If Yes, name of the contrast: | | | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/22/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C17925 | Imaging contrast agent dose | ImgContrastAgentDose | Dosage of the contrast agent used | Contrast Used: If Yes, dosage | | | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C18708 | Imaging pulse sequence other text | ImgPulseSeqOTH | The free-text field related to 'Imaging pulse sequence type' specifying other text. Type of imaging pulse sequence used | Other, specify | | | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 1.0 | 5/27/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C02499 | Imaging pulse sequence type | ImgPulseSeqTyp | Type of imaging pulse sequence used | DTI sequence parameters, Sequence: | Spin echo;STEAM;Other, specify; | Spin echo;STEAM;Other, specify; | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 3.0 | 8/28/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging sequence type | | Multiple Pre-Defined Values Selected | | | | | | | |
C10685 | Imaging slice orientation type | ImgSliceOrientTyp | The slice orientation used in imaging acquisition | DTI sequence parameters, Slice orientation: | Axial;Coronal;Sagittal;Oblique;Other, specify; | Axial;Coronal;Sagittal;Oblique;Other, specify; | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging slice orientation type | | Single Pre-Defined Value Selected | | | | | | | |
C18719 | Imaging slice orientation other text | ImgSliceOrientOTH | The free-text field related to 'Imaging slice orientation type' specifying other text. The slice orientation used in imaging acquisition | Other, specify | | | Alphanumeric | No instructions available | No references available | Adult;Pediatric | Supplemental | 1.0 | 5/27/2014 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | 4000 | Free-Form Entry | | | | | | | |
C18611 | Imaging field of view axis 2 measurement | ImgFieldViewAxis2Measr | Axis 2 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Field of view | | | Numeric Values | DTI sequence parameters | No references available | Adult;Pediatric | Supplemental | 1.0 | 9/12/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | | Free-Form Entry | | | millimeter | | | | |
C08241 | Imaging field of view axis 1 measurement | ImgFieldViewAxis1Measr | Axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | DTI sequence parameters, Field of view | | | Numeric Values | Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2) | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/25/2013 | FOV | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging field of view measurement | | Free-Form Entry | | | millimeter | | | | |
C18610 | Imaging in plane resolution axis 2 measurement | ImgInPlaneRsltnAxis2Measr | Axis 2 of in-plane spatial resolution used in imaging acquisition | In-plane resolution | | | Numeric Values | DTI sequence parameters | No references available | Adult;Pediatric | Supplemental | 1.0 | 9/12/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | | | Free-Form Entry | | | millimeter | | | | |
C10576 | Imaging in plane resolution axis 1 measurement | ImgInPlaneRsltnAxis1Measr | Axis 1 of in-plane spatial resolution used in imaging acquisition | DTI sequence parameters, In-plane resolution | | | Numeric Values | Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2) | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging in plane resolution measurement | | Free-Form Entry | | | millimeter | | | | |
C08244 | Imaging slice thickness value | ImgSliceThicknessVal | Value of the thickness of the slice measured in millimeters (mm) | DTI sequence parameters, Slice thickness | | | Numeric Values | Answer should be recorded in millimeters squared (mm) | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/25/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging slice thickness value | | Free-Form Entry | 0 | 99 | millimeter | | | | |
C08245 | Imaging slice count | ImgSliceCt | Count representing the total number of single image planes captured during imaging acquisition | DTI sequence parameters, Number of slices | | | Numeric Values | No instructions available | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/25/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging slice number | | Free-Form Entry | | | | | | | |
C08238 | Imaging repetition gap value | ImgRepetitionGapVal | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | DTI sequence parameters, Repetition time | | | Numeric Values | TR | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/25/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging repetition time | | Free-Form Entry | | | millisecond | | | | |
C08239 | Imaging echo duration | ImgEchoDur | Duration between the application of the 90 degree pulse and the peak of the echo signal, in milliseconds, during the spin echo and inversion recovery pulse sequences in imaging acquisition | DTI sequence parameters, Echo time | | | Numeric Values | TE | No references available | Adult;Pediatric | Supplemental | 3.0 | 7/24/2013 | Aliases for variable name not defined | Diffusion Tensor Imaging (DTI) | | Imaging Diagnostics | Assessments and Examinations | Imaging echo time | | Free-Form Entry | | | millisecond | | | | |